WEATHERING: 2,000 hours weatherometer - no cracking, crazing,
or erosion, slight chalking. ASTM D638
TEMPERATURE CYCLING and PENETRATION: Tests conducted in
accordance with the "Acceptance Criteria For Special Roofing Systems"
as published by the International Conference of Building Officials
(ICBO). Results: PASS. Samples averaged 1.626 before testing. Samples
averaged 1.610 after being subjected to the Weatherometer. The change
in thickness was less than 1%. Examination of the samples after
testing showed no evidence of tearing or cracking of the protective
coating.
*Temperature Cycling and Penetration Testing: 25 continuous cycles
of 1 hour of water exposure at room temperature prior to 6 hours
at -40° F, 2 hours at 70° F, 14 hours at 180° F and
1 hour at 70° F. Spray nozzles delivered 6 in. of water per
hour at a temperature of 40° F to 60° F. At the conclusion
of the 25 cycles the specimens were examined.
FLASH POINT: No Flash at 200° F (water-based). ASTM
1310, Tag Open Cup
FLEXIBILITY: Low Temperature Flexibility: pass 1": -40°
F ASTM C836
TENSILE: *Includes Metacrylics stitchbonded polyester fabric
(10 mils) Strength: 156 psi (81 mils*); Strength at break 1,914
psi 74° F ASTM D412 (10 mils) Elongation:149% ave(81 mils*)Strength
at break 3,540 psi , 0° F ASTM D412
HARDNESS: Shore A 41 ASTM D-676 (8 days cure + 4 hours 120°
F)
PEEL ADHESION: Concrete: 6.3 average lbs./linear inch ASTM
C836
PERMEABILITY: 0.016 Perms ASTM D1653 (81 mils dry film thickness)
WIND UPLIFT: 105 PSF Section 6 of ANSI A58.1, Min. Design
Loads for Building and Other Structures
FIRE RESISTANCE: Class A ASTM E-108 UL Standard 790 (1,400°
F Flame & Wind Velocity 1,050 ft./minute)
CHEMICAL RESISTANCE:
Gasoline - some softening and spotting
Lubricating Oil - some spotting
1% Sodium hydroxide alkali - no effect
Diesel - no effect
1% Hydrochloric acid - no effect
Stoklard solvent - no effect
Sodium chloride (salt) - no effect
Boric acid - no effect
Petroleum ether (naptha) - no effect
SAYBOLT FUROL: At 122oF is 265 Sec. AASHTOT 59
DEMULSIBILITY: No reaction AASHTOT 59
PARTICLE CHARGE: Negative
TOXICITY: Not for use with potable water
WEIGHT: 12.1 lbs./gallon
VOC (Volatile Organic Content): 57.43 grams/liter
SOLIDS CONTENT (by weight): 68.4% FTMS 141, Method 4041
SURFACE PREPARATION: Surfaces should be clean, dry, free
of dust, dirt and oily residues. Remove loose rust from metal, and
wipe new galvanized metal with acidic acid solution prior to application.
Metacrylics Primer is recommended for all surfaces. New concrete
must be fully cured. New glazed asphalt and torch down single-ply
assemblies should wait 6 months or more before application.
SPRAY APPLICATION and COVERAGE RATES: Apply 2 coats of White
@ 2 gallons/100 sq. ft. per application (total 4 gallons/100 sq.ft.)
using a .035 - .039 spray tip. Allow 12-24 hours between applications.
Hints: Don't spray on windy days! Use barricades around the job.
Visqueen all skylights, etc. not to be coated. Be sure to have 1/2
a barrel of water to flush the pump and hose when finished. Be sure
to have extra tips and TSL Throat Seal Liquid. Carefully pour a
1/4" layer of water over the drum of Acrylic White to prevent skinning
over.
ROLLER APPLICATION and COVERAGE RATES: Apply 3 coats @ 1-1/3
gals /100 sq. ft. per application (total of 4 gals/100 sq. ft.).
Allow 12 to 24 hrs between applications.
NON-SKID APPLICATION: Sand may be gently broadcasted over
the wet acrylic White, or mix 1/2 gallon of #30 mesh sand, rubber
granules, etc., with 2 to 1/2 gallons of acrylic Color, using a
stick or electric drill with mixing paddle. Add more or less sand
to desired consistency. Apply with a texture roller or texture gun.
HINTS: Allow 24 hours drying time or dry enough to walk
on. Cold temperatures slow down the drying times. Start early, stop
early! Application in hot temperatures should be avoided or blistering
of the coating may occur. If any Acrylic White is left over, apply
additional coats until all product is used. 4 gallons per 100 sq.
ft. is necessary to prevent delamination in ponding areas and to
maintain superior performance under UV and freezing conditions.
CLEAN-UP: Clean tools and equipment with water. Cured material
may be removed with Amylacetate, hand cleaner, or lacquer thinner.
Do not use these materials (except hand cleaner) on bare skin.
THINNING: Thin with water if necessary
STORAGE: Store in areas where temperature remains above
40oF. Prior to use, agitate for 2-3 minutes by hand or
machine. Reseal opened containers. If contents skin, remove skin,
agitate and use immediately. If the product has been stored for
a months (or years), remove any surface skin that may have developed,
stir, and immediately use.
IMPORTANT APPLICATION INFORMATION:
DO NOT APPLY if rain or freezing weather is imminent within 24
hours following application, or during fog or drizzle. PROTECT materials
from freezing & extreme heat. This product is water-based and could
wash off if not fully cured.
DO NOT APPLY when temps are consistently below 40° F. The Acrylic
Base dries slowly when temps are below 55° F. Areas shaded from
sunlight dry very slowly. Seventy-two hours or more may be required
for proper curing.
DO NOT THIN or add solvents.
KEEP AWAY FROM CHILDREN.
CAUTION! Wet acrylic is extremely slippery when stepped on. Use
a safety rope around you on sloped surfaces.
Always stir the Metacrylics Primer before any application. Do not
stir the Gel. Usually the Base and Topcoats do not need stirring
before application.
==================NOTICE=================
Metacrylics products must be applied and installed according to
written specifications from the manufacturer. Metacrylics assumes
no liability for failures of this roof/deck system resulting from
deviation from manufacturer's written specification, poor workmanship,
or delamination of an existing underlying roof/deck membrane. The
manufacturer makes no warranty of any kind, express or implied,
concerning this roof/deck system, if it is not used according to
manufacturer's specifications.
MANUFACTURER: METACRYLICS, 142 N. 27th Street, San Jose,
California 95116 Office: (408) 280-7733 fax: (408) 280-6329
SOURCES FOR THE INFORMATION PRESENTED ABOVE ARE:
ASTM and FTMS performed by Underwriters Laboratories, Inc., Cal
Coast Laboratories, Inc., Harlan Associates, Inc., State of Calif.
Dept. of Transportation (Division of Structures and Engineering
Services) Office of Transportation Laboratory, Sacramento, CA; State
of Calif. Air Resources Board, Sacramento, CA; State of Calif. Dept.
of Health; State of Calif. Bay Area Air Pollution Control Dist.;
field experience of construction contractors and California Builder
& Engineer. Metacrylics is not responsible for any changes in
the above data due to discovered data or changes in the above tests.